Frame1

Photogallery Laboratory Overview.

Photogallery from neutron scattering test run #1.

Photogallery from neutron scattering test runi #2.

Final version for H(n,n)H paper pdf with "final" figures converted by Acrobat 2/4/2010

Final draft version for H(n,n)H paper pdf converted by Acrobat 2/2/2010

Final draft version for H(n,n)H paper pdf version 1.3 2/2/2010

Final draft version for H(n,n)H paper postscript verstion 2/2/2010

H(n,n)H Data from September 2006 Run


Tag and Event File 9260

Tag and Event File 9261

Tag and Event File 9262

Tag and Event File 9270

Tag and Event File 9271

Tag and Event File 9272

Tag and Event File 9273

Tag and Event File 9274

Tag and Event File 9290

Tag and Event File 9291

Tag and Event File 9292

Tag and Event File 9294

Tag and Event File 0020

Tag and Event File 0021

Tag and Event File 0022

Tag and Event File 0030

Tag and Event File 0031

Tag and Event File 0032

Tag and Event File 0040

Tag and Event File 0041

Tag and Event File 0050

Tag and Event File 0051

Tag and Event File 0060

Tag and Event File 0070

Tag and Event File 0090

Tag and Event File 0100

Tag and Event File 0101

Tag and Event File 0102

Tag and Event File 0110

Tag and Event File 0120

Tag and Event File 0121

Alpha Data Tag and Event File 1020, 1021,3210, 9140, 9260 and 9262

H(n,n)H Data from August 2007 Run

Run Information

Target

BCI

Comments

Thin 2 mil

No BCI Recored

No event files recorded

Thin 2 mil

1933.1x10-5


Thin 2 mil

27500.0x10-5 +

Incorret Stop done detector telescope not synced and no tag files

Thin 2 mil

BCI Unit not turned on

Thin 2 mil

31291.7x10-5

E8 not turned on

Thin 2 mil

21766.0x10-5


Sample Out

38439.7x10-5

No Event Data Saved due to accident

Thin 2 mil

33627.1x10-5


Thin 2 mil

16370.4x10-5


Thin 2 mil

6485.6x10-5


Sample OUT

20648.7x10-5


Sample OUT

10895.0x10-5


Sample OUT

26037.7x10-5


Thin 2.0 mil

1745.7x10-5


Thin 2.0 mil

29649.6x10-5


Thin 2.0 mil

1019.1x10-5

Interupted for Salvage

Thin 2.0 mil

37068.8x10-5


Thin 2.0 Mil

25012.8x10-5

Zeros in monitor data , no bci, no monitor neutrons in files

Sample OUT

27912.7x10-5


Sample OUT

39936.1x10-5


SampleOUT

10820.3x10-5


Thin 2.0 Mil

10996.8x10-5


Thin 2.0 Mil

10463.3x10-5


Thin 2.0 Mil

18453.8x10-5


End of in beam experiments

Collimator schematics

Positives :

  • Solid angles determined without moving dectectors or collimators.

  • All detectors and collimators fixed by set screws.

Negatives:

  • No collimator between E and delta E to cut out (n,p) and (n,alpha) from silicon.

  • Need time to get things made in the shop

  • Others?


Last Modified 10/16/98 by T. N. Massey / massey@ohio.edu


View Site in Mobile | Classic
Share by: