canonical:changeleg
Switching Extension Legs
Switching Extension Legs
-
Run current to zero and turn power to quad(s) off if needed.
-
Turn power to leg selection panel on (white lights will come on) if not already on.
-
Push button to select leg.
-
Turn power off (interlock light for beam line will change to leg selected).
-
Turn power on again.
-
Turn quad supply on (switch on right that says “lens power/off”).
-
You can now operate quad(s) for selected line.
-
NOTE Quad 4 selection between the R-23 and R-45 beamlines is NOT done by leg selector panel; this is controlled by a switch in the large target room.
NOTE: Always turn quad power off before attempting to switch legs. Switching magnet polarty must be done in a separate operation.
* Original Credits *
Maintained by:
Thomas N. Massey
Office: Accelerator Lab 217
Telephone: (740)593-0933
E-Mail: MASSEY@OHIOU.EDU
Last modified on 10/29/98