Over Voltage Trip

Indication:

The TPS OVERVOLTAGE PROTECTION “TRIPPED” red light will be on, the CHARGING CONTROLLER “DEFAULT” red light will be on, and the GVM will be at around 0.1 MV.

To Recover:

  1. Confirm that you were using the correct value on the TERMINAL VOLTAGE dial.
  2. Set the CONTROL GAIN to zero.
  3. Set the TERMINAL VOLTAGE dial to zero.
  4. Lower the CHARGING VOLTAGE dial to 0.10
  5. Press the OVERVOLTAGE PROTECTION “RESET” button. Both red lights will go out.
  6. Switch OVERVOLTAGE PROTECTION to “DISABLE”.
  7. Repeat the Accelerator Startup procedure.