playground:trip
Over Voltage Trip
Indication:
The TPS OVERVOLTAGE PROTECTION “TRIPPED” red light will be on, the CHARGING CONTROLLER “DEFAULT” red light will be on, and the GVM will be at around 0.1 MV.
To Recover:
-
Confirm that you were using the correct value on the TERMINAL VOLTAGE dial.
-
Set the CONTROL GAIN to zero.
-
Set the TERMINAL VOLTAGE dial to zero.
-
Lower the CHARGING VOLTAGE dial to 0.10
-
Press the OVERVOLTAGE PROTECTION “RESET” button. Both red lights will go out.
-
Switch OVERVOLTAGE PROTECTION to “DISABLE”.
-
Repeat the Accelerator Startup procedure.